Cell Technology, Automated Cell Counter, QuadCount™
You have not viewed any products recently.
View Larger
Cell Technology, Automated Cell Counter, QuadCount™
QuadCount Automated Cell Counter
The Accuris QuadCount improves on the simple technique of brightfield microscopy by utilizing an LED light source, precision optics and a high resolution CMOS detector. A finely tuned, motorized XYZ positioning stage provides for extra fine focusing and ability to capture multiple images.
With count speeds at fast as 20 seconds per sample, the Accuris QuadCount provides many advantages over the tedious and time consuming manual hemocytometry method. The advanced software eliminates human bias in dead/live determinations, reduces counting errors, saves time, and improves efficiency.
The QuadCount utilizes a unique 4-chambered disposable QuadSlide™. Four samples can be processed in one slide (twice the capacity of standard 2-chambered slides), decreasing consumable costs. Each chamber has a hydrophilic inner surface with an engraved grid pattern. High precision production and molding ensure that each QuadSlide meets the rigorous standards and dimensional tolerances required for optimal counting performance.
The QuadCount’s ability to analyze larger sample volumes/multiple images provides significantly better accuracy. 3-count Modes Available to analyze different sample volumes.
- Quick Mode: 0.15µL / 20 seconds (1 image frame)
- Normal Mode: 0.9µL / 30 seconds (6 image frames)
- Precise Mode: 3.6µL / 100 seconds (24 image frames)
- Advanced Optics and Imaging Technology- Accuris QuadCount incorporates the highest quality optical and electronic components, such as a 4X objective lens and 5MP CMOS detector, to ensure reliable performance and consistent results
- Autofocus- correct focus is crucial for accurate counts of viable cells
- Advanced Algorithms- advanced detection algorithms easily manage irregularly shaped and aggregated cells
- Intuitive User Interface- after images are captures, the cell count parameters are easily adjusted
- Gating size range
- Aggregation level
- Live/dead definition
|
C148-1 |
C148-1E |
Electrical |
230V / 50-60Hz |
115V / 50-60Hz |
Optics |
High quality 4x objective lens |
Pixel Resolution |
2592 x 1944 |
Image Detection |
5 mega pixel CMOS sensor |
Illumination |
Green LED (50,000 hour life) |
Sample Volume |
20μL (4 samples per QuadSlide) |
Max. Counting Volume |
3.6μL (24 image captures) |
Consumable Slide |
QuadSlide, 4-chamber |
Counting Modes/Speeds |
Quick (20 sec), Normal (30 sec), Precise (100 sec) |
Dynamic Range |
1 x 104 to 1 x 107 cells per mL |
Cell Size Range |
5 to 60μm |
Data Output |
USB drive for PDF report |
Dimensions |
6.4 x 11.5 x 8.5 inch / 16.3 x 29.3 x 21.6cm |
Weight |
11 Lbs |