Syringes, Gastight® Syringe, 1700 Series, AD/DAD AccuDil® Instrument, Hamilton
home >
chromatography >
syringes, gastight® syringe, 1700 series, ad/dad accudil® instrument, hamilton
You have not viewed any products recently.
View Larger
- There are no alternate images available for this product.
- There are no alternate images available for this product.
Syringes, Gastight® Syringe, 1700 Series, AD/DAD AccuDil® Instrument, Hamilton
The HAMILTON 1700 series is the GASTIGHT® version of the 700 series. The syringes are designed to work with liquids and gases. These syringes use PTFE as an inert plunger seal. They cover capacities from 10µl to 500µl. The syringes have an accuracy of ±1% of the nominal volume. With these syringes liquids only come into contact with glass and PTFE. The plunger assemblies are interchangeable.
Typical applications are:
• Use in diluters/dispensers
• Use in autosamplers and analysers
• Pipetting of gases
• Sample injection in GC, LC and TLC
Tech Tip
When initially inserting the plunger into a GASTIGHT® syringe barrel, wet the PTFE tip with deionised water or another solvent compatible with the sample.
Economical Tip
Plungers for GASTIGHT® syringes are easily replaceable when your glass barrel is not broken.
Syringe type Syringe capacity |
1701 10uL |
1702 25uL |
1705 50uL |
1710 100uL |
1725 250uL |
1750 500uL |
Needle length(mm) |
51 |
51 |
51 |
51 |
51 |
51 |
Needle gauge |
26s |
22s |
22s |
22s |
22s |
22 |
Needle outer diameter(mm) |
0.47 |
0.72 |
0.72 |
0.72 |
0.72 |
0.72 |
Needle inner diameter(mm) |
0.13 |
0.15 |
0.15 |
0.15 |
0.15 |
0.41 |
Needle point style |
2 |
2 |
2 |
2 |
2 |
2 |
Electro-tapered |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
Dead volume in needle(uL) |
0.68 |
0.90 |
0.90 |
0.90 |
0.90 |
6.73 |
Scale length(mm) |
60 |
60 |
60 |
60 |
60 |
60 |
Test pressure(MPa) |
0.6 |
0.6 |
0.6 |
0.6 |
0.6 |
0.6 |
Max working temperature(°C) |
50 |
50 |
50 |
50 |
50 |
50 |
Min working temperature(°C) |
20 |
20 |
20 |
20 |
20 |
20 |
Ordering Info
Cat No |
Vendor Part No |
Volume | Needle | Model |
Qty |
Price |
Qty |
UOM |
S996-12 |
201000 |
50uL | AD, AccuDil® with stop, No needles available | 1705 |
In Stock |
1 |
$64.00 |
|
EA |
S996-11 |
201050 |
100uL | AD, AccuDil® with stop, No needles available | 1710 |
In Stock |
1 |
$81.00 |
|
EA |
S996-13 |
201100 |
250uL | AD, AccuDil® with stop, No needles available | 1725 |
In Stock |
1 |
$42.00 |
|
EA |
S996-14 |
201150 |
500uL | AD, AccuDil® with stop, No needles available | 1750 |
In Stock |
1 |
$48.00 |
|
EA |
S996-15 |
201500 |
50uL | DAD, Diluter AccuDil® with stop, No needles available | 1705 |
In Stock |
1 |
$121.00 |
|
EA |
S996-16 |
201600 |
250uL | DAD, Diluter AccuDil® with stop, No needles available | 1725 |
In Stock |
1 |
$276.00 |
|
EA |
S996-17 |
201650 |
500uL | DAD, Diluter AccuDil® with stop, No needles available | 1750 |
In Stock |
1 |
$190.00 |
|
EA |
Options
Cat No |
Vendor Part No |
Description | Model | Volume |
Qty/UOM |
Price |
Qty |
UOM |
S990-1 |
7758-02 |
Standard RN needles | 1701/10uL | |
In Stock |
6 |
$58.00 |
|
PK |
S990-2 |
7758-03 |
Standard RN needles | 1702, 1705, 1710 | 25µL, 50µL, 100µL |
In Stock |
6 |
$78.00 |
|
PK |
S990-3 |
7779-03 |
Standard RN needles | 1725 | 250µL |
In Stock |
6 |
$78.00 |
|
PK |
S990-4 |
7779-01 |
Standard RN needles | 1750 | 500µL |
In Stock |
6 |
$58.00 |
|
PK |
S990-28 |
90039 |
Standard N needles | 1701 | 10µL |
In Stock |
6 |
$68.00 |
|
PK |
S990-33 |
90038 |
Standard N needles | 1702, 1705, 1710, 1725 | 25µL, 50µL, 100µL, 250µL |
In Stock |
6 |
$88.00 |
|
PK |
S990-34 |
90022 |
Standard N needles | 1750 | 500µL |
In Stock |
6 |
$68.00 |
|
PK |
S990-83 |
90139 |
Standard KF needles | 1701 | 10µL |
In Stock |
6 |
$67.00 |
|
PK |
S990-88 |
90138 |
Standard KF needles | 1702, 1705, 1710, 1725 | 25µL, 50µL, 100µL, 250µL |
In Stock |
6 |
$87.00 |
|
Pk |
S990-89 |
90122 |
Standard KF needles | 1750 | 500µL |
In Stock |
6 |
$67.00 |
|
PK |