Tetrahydrofuran ChromAR, Suitable for Liquid Chromatography and UV-Spectrophotometry (Contains no Preservative), Macron™
home >
chemicals >
tetrahydrofuran chromar, suitable for liquid chromatography and uv-spectrophotometry (contains no preservative), macron™
You have not viewed any products recently.
View Larger
- There are no alternate images available for this product.
- There are no alternate images available for this product.
Tetrahydrofuran ChromAR, Suitable for Liquid Chromatography and UV-Spectrophotometry (Contains no Preservative), Macron™
(Contains no Preservative)
Formula: C4H8O
Formula Weight: 72.11
Suitable for Liquid Chromatography and UV-Spectrophotometry
TEST |
SPECIFICATION |
Meets A.C.S. Specifications |
Assay (C4H8O) (by GC, corrected for water) |
min. 99.8% |
Peroxide (as H2O2) |
max. 0.015% |
Residue after Evaporation |
max. 5 ppm |
Water (H2O)(by KF, coulometric) |
max. 0.03% |
Optical Absorbance (1-cm path vs water): |
212 nm |
max. 1.00 |
225 nm |
max. 0.50 |
250 nm |
max. 0.17 |
300 nm |
max. 0.01 |
|
For Laboratory, Research or Manufacturing Use |
For a Certificate of Lot Analysis, visit www.avantormaterials.com. |
CAS Number |
109-99-9 |
IMO |
3:2056 |
HTS Number |
2932110000 |
Specific Gravity |
1L = .88 Kg |
Flash Point |
-14°C |
Spill Kit |
Solvent Spill Cleanup |
Storage Color Code |
Red |
Management of Change |
N |